"id": "CVE-2024-9748",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"published": "2024-11-22T21:15:28.720",
"lastModified": "2024-11-25T16:16:04.847",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tungsten Automation Power PDF XPS File Parsing Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Tungsten Automation Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of XPS files. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24464."
},
{
"lang": "es",
"value": "Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo despu\u00e9s de la liberaci\u00f3n en el an\u00e1lisis de archivos XPS de Tungsten Automation Power PDF. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Tungsten Automation Power PDF. Se requiere la interacci\u00f3n del usuario para explotar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. La falla espec\u00edfica existe en el an\u00e1lisis de archivos XPS. El problema es el resultado de la falta de validaci\u00f3n de la existencia de un objeto antes de realizar operaciones en el objeto. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. Era ZDI-CAN-24464."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-416"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:tungstenautomation:power_pdf:*:*:*:*:*:*:*:*",
"versionEndExcluding": "5.1",
"matchCriteriaId": "07AF31C9-62C2-4FCA-975B-EEFCF34B8C78"
}
]
}
]
}
],
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1339/",
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
]
}
]
}