mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 01:02:25 +00:00
108 lines
3.4 KiB
JSON
108 lines
3.4 KiB
JSON
{
|
|
"id": "CVE-2022-33319",
|
|
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"published": "2022-07-20T17:15:08.353",
|
|
"lastModified": "2022-07-27T18:56:08.897",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Una vulnerabilidad de lectura fuera de los l\u00edmites en las versiones 10.97.1 y anteriores de ICONICS GENESIS64 y en las versiones 4.04E (10.95.210.01) y anteriores de Mitsubishi Electric MC Works64 permite a un atacante remoto no autenticado divulgar informaci\u00f3n en la memoria o causar una condici\u00f3n de denegaci\u00f3n de servicio (DoS) mediante el env\u00edo de paquetes especialmente dise\u00f1ados al servidor GENESIS64"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.1,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.2
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:iconics:genesis64:10.97:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "44D3F652-C916-4395-BD11-AECDDF960D45"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:iconics:genesis64:10.97.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "6D89798E-910C-4C3F-9385-D9B7CA921091"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "10.95.210.01",
|
|
"matchCriteriaId": "F44C63DD-663E-4505-8586-D4BCAB01AF73"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://jvn.jp/vu/JVNVU96480474/index.html",
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |