mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 01:02:25 +00:00
124 lines
3.6 KiB
JSON
124 lines
3.6 KiB
JSON
{
|
|
"id": "CVE-2023-20192",
|
|
"sourceIdentifier": "ykramarz@cisco.com",
|
|
"published": "2023-06-28T15:15:10.007",
|
|
"lastModified": "2023-07-06T21:08:47.440",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Multiple vulnerabilities in Cisco Expressway Series and Cisco TelePresence Video Communication Server (VCS) could allow an authenticated attacker with Administrator-level read-only credentials to elevate their privileges to Administrator with read-write credentials on an affected system. Note: \"Cisco Expressway Series\" refers to Cisco Expressway Control (Expressway-C) devices and Cisco Expressway Edge (Expressway-E) devices. For more information about these vulnerabilities, see the Details section of this advisory."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 7.7,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.1,
|
|
"impactScore": 4.0
|
|
}
|
|
],
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "ykramarz@cisco.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.6,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.1,
|
|
"impactScore": 5.8
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-noinfo"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "ykramarz@cisco.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-20"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:cisco:telepresence_video_communication_server:*:*:*:*:expressway:*:*:*",
|
|
"versionEndIncluding": "x14.0.3",
|
|
"matchCriteriaId": "10B65B6C-EBB4-407E-803C-9F3B33B07177"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:cisco:telepresence_video_communication_server:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "x14.0.3",
|
|
"matchCriteriaId": "C5220365-49BE-4021-9D4E-13FEB6FB5EBD"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-expressway-priv-esc-Ls2B9t7b",
|
|
"source": "ykramarz@cisco.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |