"id": "CVE-2022-1522",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2022-09-06T23:15:08.307",
"lastModified": "2024-11-21T06:40:53.750",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics."
},
{
"lang": "es",
"value": "Cognex 3D-A1000 Dimensioning System en versi\u00f3n de firmware 1.0.3 (3354) y anteriores, es vulnerable a CWE-117: Neutralizaci\u00f3n Inadecuada de la Salida de los Registros, que permite a un atacante crear registros falsos que muestren que la contrase\u00f1a ha sido cambiada cuando no es as\u00ed, complicando los an\u00e1lisis forenses."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
]
},
"weaknesses": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-117"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:cognex:3d-a1000_dimensioning_system_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.0.3\\(3354\\)",
"matchCriteriaId": "BE25BB24-A1BE-4904-935B-61E84CAAFD81"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cognex:3d-a1000_dimensioning_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "01F624C6-079A-40BB-BA07-3441A6934850"
}
]
}
]
}
],
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
}
]
}