"id": "CVE-2017-17691",
"sourceIdentifier": "cve@mitre.org",
"published": "2018-09-07T22:29:00.260",
"lastModified": "2019-10-03T00:03:26.223",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 and earlier uses cleartext to exchange the username and password between server and client instances, which allows remote attackers to obtain sensitive information via a man in the middle attack."
},
{
"lang": "es",
"value": "Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 y anteriores emplea texto claro para intercambiar el nombre de usuario y la contrase\u00f1a entre las instancias del servidor y el cliente, lo que permite que atacantes remotos obtengan informaci\u00f3n sensible mediante un ataque Man-in-the-Middle (MitM)."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:contronics:homeputer_cl_studio_fur_homematic:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.0",
"matchCriteriaId": "9E8EA98F-C07B-4D72-A2FE-1E2FAC8EC904"
}
]
}
]
}
],
"references": [
{
"url": "https://www.compass-security.com/fileadmin/Datein/Research/Advisories/CSNC-2017-031_homematic.txt",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Mitigation",
"Third Party Advisory"
]
}
]
}