René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

475 lines
13 KiB
JSON

{
"id": "CVE-2017-18743",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-04-23T16:15:12.617",
"lastModified": "2020-04-27T13:37:56.260",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by authentication bypass. This affects R6300v2 before 1.0.4.8, R6400 before 1.0.1.20, R6700 before 1.0.1.20, R6900 before 1.0.1.20, R7000 before 1.0.7.10, R7100LG before V1.0.0.32, R7300DST before 1.0.0.52, R7900 before 1.0.1.16, R8000 before 1.0.3.36, R8300 before 1.0.2.94, R8500 before 1.0.2.94, WNDR3400v3 before 1.0.1.12, and WNR3500Lv2 before 1.2.0.40."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a R6300v2 versiones anteriores a 1.0.4.8, R6400 versiones anteriores a 1.0.1.20, R6700 versiones anteriores a 1.0.1.20, R6900 versiones anteriores a 1.0.1.20, R7000 versiones anteriores a 1.0.7.10, R7100LG versiones anteriores a V1.0.0.32, R7300DST versiones anteriores a 1.0.0.52, R7900 versiones anteriores a 1.0. 1.16, R8000 versiones anteriores a 1.0.3.36, R8300 versiones anteriores a 1.0.2.94, R8500 versiones anteriores a 1.0.2.94, WNDR3400v3 versiones anteriores a 1.0.1.12 y WNR3500Lv2 versiones anteriores a 1.2.0.40."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "ADJACENT_NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.8",
"matchCriteriaId": "F8097CEE-2577-4C44-9260-8B2DD2D2CA78"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.1.20",
"matchCriteriaId": "7084EC75-5CAB-4EB3-BAED-00BFF80F71D9"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.1.20",
"matchCriteriaId": "AA5CCA76-ED97-4B2E-AB06-9C9F375F7C81"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.1.20",
"matchCriteriaId": "E7A7A9C9-3505-440C-8806-E48AB316C2CC"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.7.10",
"matchCriteriaId": "B94C2A0A-F26B-4CD2-A91E-DD62C5F788B3"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.32",
"matchCriteriaId": "833A98AF-A4B0-4C68-AACD-6B3F58E64060"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r7300dst_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.52",
"matchCriteriaId": "02C2BB4F-8FBB-47BF-A05F-72DDC2D0A31B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r7300dst:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C75148EB-DE6C-4C5C-BF34-4800A66CF11C"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.1.16",
"matchCriteriaId": "628B45E0-EAE3-4ACD-82EC-8E2250F885BB"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.3.36",
"matchCriteriaId": "B91B7AB8-E499-416D-8E63-C49CDA753C3C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.2.94",
"matchCriteriaId": "A18E8950-B107-4050-AFEF-30C20F6166FA"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.2.94",
"matchCriteriaId": "58EFB06D-AD59-4F40-B6EC-BD3C1BCACE7A"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.1.12",
"matchCriteriaId": "7000113A-DA3E-4F6E-A926-4682794DBC57"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.2.0.40",
"matchCriteriaId": "8804FB5C-A72C-4413-8F74-2DCEF216F74A"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000051512/Security-Advisory-for-Authentication-Bypass-on-Some-Routers-PSV-2017-0330",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}