"id": "CVE-2017-18754",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2020-04-22T17:15:11.667",
|
|
"lastModified": "2020-04-24T20:15:27.387",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, and WNR2000v5 before 1.0.0.58."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR4300v1 versiones anteriores a 1.0.2.90 y WNR2000v5 versiones anteriores a 1.0.0.58."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.8,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 0.9,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "cve@mitre.org",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.8,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 0.9,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
|
|
"accessVector": "ADJACENT_NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 5.2
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 5.1,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-74"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.0.2.88",
|
|
"matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.0.2.90",
|
|
"matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.0.0.58",
|
|
"matchCriteriaId": "9C819040-B30C-4393-9DD4-8E5744B13050"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://kb.netgear.com/000051494/Security-Advisory-for-Post-Authentication-Command-Injection-on-Routers-PSV-2017-0329",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |