mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
475 lines
14 KiB
JSON
475 lines
14 KiB
JSON
{
|
|
"id": "CVE-2017-18791",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2020-04-21T19:15:11.897",
|
|
"lastModified": "2020-05-04T15:09:05.707",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Certain NETGEAR devices are affected by CSRF. This affects R6050/JR6150 before 1.0.1.7, PR2000 before 1.0.0.17, R6220 before 1.1.0.50, WNDR3700v5 before 1.1.0.48, JNR1010v2 before 1.1.0.40, JWNR2010v5 before 1.1.0.40, WNR1000v4 before 1.1.0.40, WNR2020 before 1.1.0.40, WNR2050 before 1.1.0.40, WNR614 before 1.1.0.40, WNR618 before 1.1.0.40, and D7000 before 1.0.1.50."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo CSRF. Esto afecta a R6050/JR6150 versiones anteriores a la versi\u00f3n 1.0.1.7, PR2000 versiones anteriores a la versi\u00f3n 1.0.0.17, R6220 versiones anteriores a la versi\u00f3n 1.1.0.50, WNDR3700v5 versiones anteriores a la versi\u00f3n 1.1.0.48, JNR1010v2 versiones anteriores a la versi\u00f3n 1.1.0.40, JWNR2010v5 versiones anteriores a 1. 1.0.40, WNR1000v4 versiones anteriores a 1.1.0.40, WNR2020 versiones anteriores a 1.1.0.40, WNR2050 versiones anteriores a 1.1.0.40, WNR614 versiones anteriores a 1.1.0.40, WNR618 versiones anteriores a 1.1.0.40, y D7000 versiones anteriores a 1.0.1.50."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "cve@mitre.org",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 6.8
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 8.6,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": true
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-352"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:r6050_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.0.1.7",
|
|
"matchCriteriaId": "50342285-48EB-4FF5-8068-CD819017FB19"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:r6050:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "363D4DEE-98B9-4294-B241-1613CAD1A3A7"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:jr6150_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.0.1.7",
|
|
"matchCriteriaId": "C733375E-342E-426B-A529-3271D03D1268"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:jr6150:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D67167E5-81D2-4892-AF41-CBB6271232D1"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:pr2000_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.0.0.17",
|
|
"matchCriteriaId": "B47967D5-4D5A-4489-BE54-19765D386612"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:pr2000:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "2451CC0C-71B2-474D-93F0-2B2ACD802FE3"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.50",
|
|
"matchCriteriaId": "E464FF8D-6202-40BA-9740-9CCE2BC23607"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.48",
|
|
"matchCriteriaId": "DD1F416B-C938-4AE3-B93E-03087575FF40"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wndr3700:v5:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "EC5B6CB8-D439-42D5-ACAE-6246874EA5F0"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:jnr1010_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.40",
|
|
"matchCriteriaId": "B13F80BA-F4DF-4728-8591-CDEEE82BDF9E"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:jnr1010:v2:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "CCE79B3F-8667-43C9-962D-EE089428F144"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:jwnr2010_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.40",
|
|
"matchCriteriaId": "52C2DA42-3B95-43B4-AB3B-103607B44C33"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:jwnr2010:v5:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7399E5E9-40D8-4ECD-8B7B-C96A27E10282"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wnr1000_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.40",
|
|
"matchCriteriaId": "18CB70FD-790E-4342-962A-2C9D8991B3C1"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wnr1000:v4:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C8218868-273B-46DB-B636-D3F9A3768069"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wnr2020_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.40",
|
|
"matchCriteriaId": "764C3E34-DDED-4530-A314-0D99226B9E1C"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wnr2020:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C2189628-03E7-445A-9EF2-656A85539115"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wnr2050_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.40",
|
|
"matchCriteriaId": "013EA9F3-64C4-4F06-989D-D00D86CF555F"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wnr2050:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "9877579C-D214-4605-93AA-2B78914CF33C"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wnr614_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.40",
|
|
"matchCriteriaId": "7B8E442A-011A-4AA0-A3D4-874BEF31702B"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wnr614:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "EC8A668E-4A30-4364-AF7A-F3C814BBAACA"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:wnr618_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.1.0.40",
|
|
"matchCriteriaId": "40488E8A-95D8-4D1B-B8C8-DEA3330D575A"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:wnr618:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7BAA7BF1-2DFE-4ADA-B3A7-F33EEAAC5962"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.0.1.50",
|
|
"matchCriteriaId": "4A94DD9D-0F07-4FD7-B1B0-1DD1E319B092"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "AF04B65B-9685-4595-9C71-0F77AD7109BE"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://kb.netgear.com/000049371/Security-Advisory-for-Cross-Site-Request-Forgery-Vulnerability-on-D7000-and-Some-Routers-PSV-2017-0386",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |