René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

132 lines
3.8 KiB
JSON

{
"id": "CVE-2017-6033",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2017-04-07T22:59:01.840",
"lastModified": "2019-10-09T23:28:35.967",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path."
},
{
"lang": "es",
"value": "Se ha descubierto un problema de secuestro de DLL en el software Schneider Electric Interactive Graphical SCADA System (IGSS), versi\u00f3n 12 y versiones anteriores. El software ejecutar\u00e1 un archivo malicioso si se le asigna el mismo nombre que un archivo leg\u00edtimo y se coloca en una ubicaci\u00f3n anterior a la ruta de b\u00fasqueda."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
},
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
"versionEndIncluding": "12.0",
"matchCriteriaId": "DA1E8EFC-6060-4BA0-95E5-81BBC3AF1353"
}
]
}
]
}
],
"references": [
{
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-01",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
]
},
{
"url": "http://www.securityfocus.com/bid/97389",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-01",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
]
}
]
}