René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

447 lines
13 KiB
JSON

{
"id": "CVE-2019-20726",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-04-16T19:15:25.527",
"lastModified": "2020-08-24T17:37:01.140",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D3600 before 1.0.0.75, D6000 before 1.0.0.75, D6100 before 1.0.0.63, R7800 before 1.0.2.52, R8900 before 1.0.4.2, R9000 before 1.0.4.2, WNDR3700v4 before 1.0.2.102, WNDR4300v1 before 1.0.2.104, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.68, and XR500 before 2.3.2.32."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.75, D6000 versiones anteriores a 1.0.0.75, D6100 versiones anteriores a 1.0.0.63, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, WNDR3700v4 versiones anteriores a 1. 0.2.102, WNDR4300v1 versiones anteriores a 1.0.2.104, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.68, y XR500 versiones anteriores a 2.3.2.32."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"accessVector": "ADJACENT_NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 5.1,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.75",
"matchCriteriaId": "6D38D448-A21A-4AB2-A641-A295EDBF6631"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.75",
"matchCriteriaId": "EF892705-E77B-470C-8262-3579349D5F32"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.63",
"matchCriteriaId": "8DE5478F-11CE-4730-AC60-64ACE7BBB03A"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.2.52",
"matchCriteriaId": "2C2195F1-18F6-4397-9D28-7A92003B7A76"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.2",
"matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.2",
"matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.2.102",
"matchCriteriaId": "FD376891-1FB6-48B7-A4B3-C3C2C6E92C39"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.2.104",
"matchCriteriaId": "9FFDF78E-8CC6-47B8-B70D-352F778CBF2C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.58",
"matchCriteriaId": "1DA490CC-DB27-4817-A589-61A0D221E9FD"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.58",
"matchCriteriaId": "652D8CA8-B56A-4403-B072-B4C245AB8EDA"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.68",
"matchCriteriaId": "2D01DCF3-B6FD-4779-B048-DA4A963C9DEB"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
"matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.3.2.32",
"matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000061202/Security-Advisory-for-Post-Authentication-Command-on-Some-Routers-and-Gateways-PSV-2018-0141",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}