"id": "CVE-2019-5014",
"sourceIdentifier": "talos-cna@cisco.com",
"published": "2019-05-08T17:29:01.410",
"lastModified": "2022-06-13T18:45:30.930",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An exploitable improper access control vulnerability exists in the bluetooth low energy functionality of Winco Fireworks FireFly FW-1007 V2.0. An attacker can connect to the device to trigger this vulnerability."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de control de acceso incorrecto explotable en la funcionalidad bluetooth low energy de Winco Fireworks FireFly FW-1007 versi\u00f3n V2.0. Un atacante puede conectarse al dispositivo para activar esta vulnerabilidad."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
],
"cvssMetricV30": [
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"accessVector": "ADJACENT_NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3
},
"baseSeverity": "LOW",
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
},
{
"source": "talos-cna@cisco.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:wincofireworks:fw-1007_firmware:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "BFD423A3-6844-4E96-8BA9-6BA3C25E25D5"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:wincofireworks:fw-1007:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B84764D3-97C7-4E52-9AF6-D614424F108C"
}
]
}
]
}
],
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0772",
"source": "talos-cna@cisco.com",
"tags": [
"Third Party Advisory"
]
}
]
}