"id": "CVE-2022-41664",
"sourceIdentifier": "productcert@siemens.com",
"published": "2022-11-08T11:15:11.813",
"lastModified": "2023-06-13T09:15:15.310",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V14.1.0.4), \nTeamcenter Visualization V13.2 (Todas las versiones &lt; V13.2.0.12), \nTeamcenter Visualization V13.3 (Todas las versiones &lt; V13.3.0. 7), \nTeamcenter Visualization V14.0 (todas las versiones &lt; V14.0.0.3), \nTeamcenter Visualization V14.1 (todas las versiones &lt; V14.1.0.4). \nLa aplicaci\u00f3n afectada contiene una vulnerabilidad de desbordamiento del b\u00fafer que podr\u00eda activarse al analizar archivos PDF especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"versionEndExcluding": "14.1.0.4",
"matchCriteriaId": "FD5EAF75-B0F4-4792-9833-085B9D830FCE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "13.3.0",
"versionEndExcluding": "13.3.0.7",
"matchCriteriaId": "FB99D790-4F55-48F2-902B-8739CAEC78EE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.0",
"versionEndExcluding": "14.0.0.3",
"matchCriteriaId": "0F811DB6-3650-4BCB-A538-AAECF63EA085"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.1",
"versionEndExcluding": "14.1.0.4",
"matchCriteriaId": "175648D0-81ED-4AC9-AF2D-4C9E93814C36"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}