"id": "CVE-2018-0155",
"sourceIdentifier": "psirt@cisco.com",
"published": "2018-03-28T22:29:00.420",
"lastModified": "2025-01-27T20:10:19.450",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Bidirectional Forwarding Detection (BFD) offload implementation of Cisco Catalyst 4500 Series Switches and Cisco Catalyst 4500-X Series Switches could allow an unauthenticated, remote attacker to cause a crash of the iosd process, causing a denial of service (DoS) condition. The vulnerability is due to insufficient error handling when the BFD header in a BFD packet is incomplete. An attacker could exploit this vulnerability by sending a crafted BFD message to or across an affected switch. A successful exploit could allow the attacker to trigger a reload of the system. This vulnerability affects Catalyst 4500 Supervisor Engine 6-E (K5), Catalyst 4500 Supervisor Engine 6L-E (K10), Catalyst 4500 Supervisor Engine 7-E (K10), Catalyst 4500 Supervisor Engine 7L-E (K10), Catalyst 4500E Supervisor Engine 8-E (K10), Catalyst 4500E Supervisor Engine 8L-E (K10), Catalyst 4500E Supervisor Engine 9-E (K10), Catalyst 4500-X Series Switches (K10), Catalyst 4900M Switch (K5), Catalyst 4948E Ethernet Switch (K5). Cisco Bug IDs: CSCvc40729."
},
{
"lang": "es",
"value": "Una vulnerabilidad en la implementaci\u00f3n de la descarga Bidirectional Forwarding Detection (BFD) de Cisco Catalyst 4500 Series Switches y Cisco Catalyst 4500-X Series Switches podr\u00eda permitir que un atacante remoto no autenticado provoque el cierre inesperado del proceso iosd, lo que provocar\u00eda una denegaci\u00f3n de servicio (DoS). La vulnerabilidad se debe a la gesti\u00f3n insuficiente de errores cuando la cabecera BFD de un paquete BFD est\u00e1 incompleta. Un atacante podr\u00eda explotar esta vulnerabilidad enviando un mensaje BFD manipulado a un switch afectado o a trav\u00e9s de \u00e9l. Un exploit con \u00e9xito podr\u00eda permitir que el atacante cause el reinicio del sistema. Esta vulnerabilidad afecta a Catalyst 4500 Supervisor Engine 6-E (K5), Catalyst 4500 Supervisor Engine 6L-E (K10), Catalyst 4500 Supervisor Engine 7-E (K10), Catalyst 4500 Supervisor Engine 7L-E (K10), Catalyst 4500E Supervisor Engine 8-E (K10), Catalyst 4500E Supervisor Engine 8L-E (K10), Catalyst 4500E Supervisor Engine 9-E (K10), Catalyst 4500-X Series Switches (K10), Catalyst 4900M Switch (K5) y Catalyst 4948E Ethernet Switch (K5). Cisco Bug IDs: CSCvc40729."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 4.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"baseScore": 7.8,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"cisaExploitAdd": "2022-03-03",
"cisaActionDue": "2022-03-17",
"cisaRequiredAction": "Apply updates per vendor instructions.",
"cisaVulnerabilityName": "Cisco Catalyst Bidirectional Forwarding Detection Denial-of-Service Vulnerability",
"weaknesses": [
{
"source": "psirt@cisco.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-388"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-755"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:cisco:ios:3.6\\(2\\)e:*:*:*:*:*:*:*",
"matchCriteriaId": "3ACD48AE-B818-40CE-848B-90B9BF1D4255"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:cisco:ios_xe:3.6\\(2\\)e:*:*:*:*:*:*:*",
"matchCriteriaId": "0D9506FB-B290-44AF-80A1-F698BEC3CBC0"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4500-x_series_switches_\\(k10\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "D720B575-15F7-49CA-AA2F-8594982DF9A0"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4500_supervisor_engine_6-e_\\(k5\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "D0C6A995-0878-49E6-B314-2278C8EB0E7E"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4500_supervisor_engine_6l-e_\\(k10\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "06BF802C-C57A-402C-8EC2-E6176CB0FF86"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4500_supervisor_engine_7-e_\\(k10\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "9832B73C-116D-4F81-9DE8-1BA930648E3F"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4500_supervisor_engine_7l-e_\\(k10\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "43AB5E31-8D8F-4009-9D6D-23C03EC9319A"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4500e_supervisor_engine_8-e_\\(k10\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "663DCB07-F6B6-4DC6-8373-742A7C117E44"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4500e_supervisor_engine_8l-e_\\(k10\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "229DF042-CEF2-4D1E-9197-3656919BF917"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4500e_supervisor_engine_9-e_\\(k10\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "D8F261DC-26E4-48DC-A900-C41BF6CB4557"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4900m_switch_\\(k5\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "CF434413-83D7-4D41-B9BF-4DF258B491E0"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:cisco:catalyst_4948e_ethernet_switch_\\(k5\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "BC27EF7D-924D-493C-B3C3-AC17EE9E5D44"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:cisco:ios:3.6\\(2\\)e:*:*:*:*:*:*:*",
"matchCriteriaId": "3ACD48AE-B818-40CE-848B-90B9BF1D4255"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:cisco:ios_xe:3.6\\(2\\)e:*:*:*:*:*:*:*",
"matchCriteriaId": "0D9506FB-B290-44AF-80A1-F698BEC3CBC0"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:rockwellautomation:allen-bradley_stratix_8300_industrial_managed_ethernet_switch:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E96AE552-ABC5-4101-ACF6-B7F20FFB4043"
}
]
}
]
}
],
"references": [
{
"url": "http://www.securityfocus.com/bid/103565",
"source": "psirt@cisco.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "http://www.securitytracker.com/id/1040587",
"source": "psirt@cisco.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-05",
"source": "psirt@cisco.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180328-bfd",
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "http://www.securityfocus.com/bid/103565",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "http://www.securitytracker.com/id/1040587",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-05",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180328-bfd",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}