"id": "CVE-2021-25643",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-05-26T21:15:08.273",
"lastModified": "2024-11-21T05:55:11.947",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Couchbase Server 5.x and 6.x before 6.5.2 and 6.6.x before 6.6.2. Internal users with administrator privileges, @cbq-engine-cbauth and @index-cbauth, leak credentials in cleartext in the indexer.log file when they make a /listCreateTokens, /listRebalanceTokens, or /listMetadataTokens call."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en Couchbase Server versiones 5.x y versiones 6.x anteriores a 6.5.2 y versiones 6.6.x anteriores a 6.6.2. Los usuarios internos con privilegios de administrador, @cbq-engine-cbauth y @index-cbauth, filtran credenciales en texto sin cifrar del archivo indexer.log cuando realizan una llamada /listCreateTokens, /listRebalanceTokens o /listMetadataTokens"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"baseScore": 4.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:couchbase:couchbase_server:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.0.0",
"versionEndExcluding": "6.5.2",
"matchCriteriaId": "5F801B3C-C4FE-46FB-89FA-2718EA5431EA"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:couchbase:couchbase_server:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.6.0",
"versionEndExcluding": "6.6.2",
"matchCriteriaId": "CA1D38E8-0E51-47FE-98BC-AFFAFE71380E"
}
]
}
]
}
],
"references": [
{
"url": "https://www.couchbase.com/resources/security#SecurityAlerts",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.couchbase.com/resources/security#SecurityAlerts",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}