"id": "CVE-2014-0751",
|
|
"sourceIdentifier": "ics-cert@hq.dhs.gov",
|
|
"published": "2014-01-25T22:55:04.583",
|
|
"lastModified": "2014-02-21T05:06:26.877",
|
|
"vulnStatus": "Modified",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Vulnerabilidad de salto de directorio en CimWebServer.exe (tambi\u00e9n conocido como el componente WebView) en GE Intelligent Platforms Proficy HMI / SCADA - CIMPLICITY anterior a 8.2 SIM 24 y Proficy Process con CIMPLICITY, permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de un mensaje manipulado a puerto TCP 10212 , tambi\u00e9n conocido como ZDI-CAN-1623."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 7.5
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-22"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\%2fscada_cimplicity:*:sim24:*:*:*:*:*:*",
|
|
"versionEndIncluding": "8.2",
|
|
"matchCriteriaId": "4C5EDB9D-01CD-4843-86CD-C834B726ACF1"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:4.01:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "6C0B8CA7-2161-4603-B844-DE6C079DF36F"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:7.5:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E3BACB11-5CD3-4CA6-9C56-D71628CADF0F"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "90538C50-38BD-4EE5-BD30-96E2E2951FE3"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "CB261867-B9B1-4D3D-B2DE-3CC3164EFD06"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.2:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "559DCD7A-0745-4D4C-A77A-83240EF6C510"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_process_systems_with_cimplicity:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "AD9711EA-2C95-41FA-8827-01FCB0ED4B06"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01",
|
|
"source": "ics-cert@hq.dhs.gov"
|
|
},
|
|
{
|
|
"url": "http://support.ge-ip.com/support/index?page=kbchannel&id=KB15940",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://www.securityfocus.com/bid/65117",
|
|
"source": "ics-cert@hq.dhs.gov"
|
|
}
|
|
]
|
|
} |