mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-29 01:31:20 +00:00
195 lines
6.0 KiB
JSON
195 lines
6.0 KiB
JSON
{
|
|
"id": "CVE-2023-29410",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2023-04-18T22:15:08.067",
|
|
"lastModified": "2023-04-28T01:25:19.217",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "\nA CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated\nattacker to gain the same privilege as the application on the server when a malicious payload is\nprovided over HTTP for the server to execute. \n\n \n\n\n\n"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.2,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-20"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.16",
|
|
"matchCriteriaId": "371B602D-2BB3-41CF-B07B-558B74AEC130"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:1.16:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "698CF5CB-17DC-405B-9C44-675A80320A65"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:insighthome_firmware:1.16:build_004:*:*:*:*:*:*",
|
|
"matchCriteriaId": "039691CA-D243-4D6D-912A-F130F7F6491C"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:insighthome:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "37CAC057-7F0E-4375-99FE-AEE0EDDEA568"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.16",
|
|
"matchCriteriaId": "18E2843D-745F-41D7-8B16-2CC18EC64290"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:1.16:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F90B0024-6C86-4E85-AE83-F349D34E7416"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:insightfacility_firmware:1.16:build_004:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D81ACD8E-4B04-4BCB-894F-4A5828899C16"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:insightfacility:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F5011815-3D43-4AA4-9395-31788D06DA10"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.16",
|
|
"matchCriteriaId": "3524289C-ACF3-424E-9A1E-A777EBFB89F1"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:1.16:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "62314597-62BC-4531-B5C8-61343262CE9E"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:conext_gateway_firmware:1.16:build_004:*:*:*:*:*:*",
|
|
"matchCriteriaId": "AD27299F-4422-4176-9DFD-86F2E4487366"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:conext_gateway:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E013171F-2BFB-4CB2-9C4B-4EB60A40B255"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-02.pdf",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |