2024-11-23 15:12:23 +00:00

213 lines
6.8 KiB
JSON

{
"id": "CVE-2022-26507",
"sourceIdentifier": "cve@mitre.org",
"published": "2022-04-14T13:15:11.637",
"lastModified": "2024-11-21T06:54:04.920",
"vulnStatus": "Modified",
"cveTags": [
{
"sourceIdentifier": "cve@mitre.org",
"tags": [
"unsupported-when-assigned"
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer"
},
{
"lang": "es",
"value": "** NO SOPORTADO CUANDO SE ASIGN\u00d3 ** Se presenta un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria en XML Decompression DecodeTreeBlock en AT&T Labs Xmill versi\u00f3n 0.7. Un archivo de entrada dise\u00f1ado puede conllevar a una ejecuci\u00f3n de c\u00f3digo remota. Esto no es lo mismo que cualquiera de: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, o CVE-2021-21830. NOTA: Esta vulnerabilidad s\u00f3lo afecta a productos que ya no son soportados por el mantenedor"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"baseScore": 7.5,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:att:xmill:0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "4CC987F6-AAFA-4CDE-842D-EA7858A3E7F4"
}
]
}
]
},
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"versionEndExcluding": "15.1",
"matchCriteriaId": "8DCC0C29-32C2-4463-B98F-AB4B56FF5314"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*",
"matchCriteriaId": "78F6B1CC-488B-48E8-B96B-77A1894E9E92"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2021",
"matchCriteriaId": "FAB4A9EC-96A2-424D-A858-162E662EBEFB"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3FFDF36B-30A5-4B35-956C-60DC15CE7EE4"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F51A7887-4F1A-428C-9E68-260E7262A678"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58BACC54-6609-4DCE-AEEC-A9C2396635A0"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FFDF44F3-2514-4CB0-A1A4-87123225B0F1"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F5CDC99-C4C8-43FE-8EA7-65C7EDFD9BA3"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE4172DF-94E3-4AEE-8D6B-9F48DC453B9E"
}
]
}
]
}
],
"references": [
{
"url": "https://Claroty.com",
"source": "cve@mitre.org",
"tags": [
"Not Applicable",
"Third Party Advisory"
]
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02",
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Release Notes",
"Third Party Advisory"
]
},
{
"url": "https://Claroty.com",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable",
"Third Party Advisory"
]
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Release Notes",
"Third Party Advisory"
]
}
]
}