"lang": "en",
"value": "There is a command injection vulnerability of ZTE's ZXCLOUD iRAI. Due to the \u00a0program \u00a0failed to adequately validate the user's input, an attacker could exploit this vulnerability \u00a0to escalate local privileges.\n\n\n"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de inyecci\u00f3n de comandos en ZXCLOUD iRAI de ZTE. Debido a que el programa no pudo validar adecuadamente la entrada del usuario, un atacante podr\u00eda aprovechar esta vulnerabilidad para escalar los privilegios locales."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "psirt@zte.com.cn",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"attackVector": "PHYSICAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "LOW"
},
"exploitabilityScore": 0.9,
"impactScore": 3.4
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "psirt@zte.com.cn",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-94"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-94"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:zte:zxcloud_irai_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "7.23.32",
"matchCriteriaId": "FC0DCC6B-32B8-4C28-BDAF-37604BA1ABFC"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:zte:zxcloud_irai:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6D48BE8C-7C78-41D7-87F1-22BFB91E3A5C"
}
]
}
]
}
],
"references": [
{
"url": "https://support.zte.com.cn/support/news/LoopholeInfoDetail.aspx?newsId=1034404",
"source": "psirt@zte.com.cn",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://support.zte.com.cn/support/news/LoopholeInfoDetail.aspx?newsId=1034404",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}