"id": "CVE-2024-12833",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"published": "2025-02-11T20:15:34.077",
"lastModified": "2025-02-18T21:39:31.887",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Paessler PRTG Network Monitor SNMP Cross-Site Scripting Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Paessler PRTG Network Monitor. Some user interaction on the part of an administrator is required to exploit this vulnerability.\n\nThe specific flaw exists within the PRTG Network Monitor web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-23371."
},
{
"lang": "es",
"value": "Vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n mediante Cross-Site Scripting SNMP en Paessler PRTG Network Monitor. Esta vulnerabilidad permite a los atacantes adyacentes a la red omitir la autenticaci\u00f3n en las instalaciones afectadas de Paessler PRTG Network Monitor. Se requiere cierta interacci\u00f3n del usuario por parte de un administrador para explotar esta vulnerabilidad. La falla espec\u00edfica existe dentro de la interfaz web de PRTG Network Monitor. El problema es el resultado de la falta de una validaci\u00f3n adecuada de los datos proporcionados por el usuario, lo que puede llevar a la inyecci\u00f3n de una secuencia de comandos arbitraria. Un atacante puede aprovechar esta vulnerabilidad para omitir la autenticaci\u00f3n en el sistema. Era ZDI-CAN-23371."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7
}
],
"cvssMetricV30": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.1,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:paessler:prtg_network_monitor:*:*:*:*:*:*:*:*",
"versionEndExcluding": "25.1.102.1373",
"matchCriteriaId": "0955FE55-AD08-4BEF-829E-A1FC9ADAACBB"
}
]
}
]
}
],
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1736/",
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
]
}
]
}