2025-03-16 03:03:50 +00:00

154 lines
4.8 KiB
JSON

{
"id": "CVE-2024-1606",
"sourceIdentifier": "cvd@cert.pl",
"published": "2024-03-18T10:15:20.863",
"lastModified": "2025-03-06T19:38:53.547",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Lack of input sanitization in BMC Control-M branches 9.0.20 and 9.0.21 allows logged-in users for\u00a0manipulation of generated web pages via injection of HTML code. This might lead to a successful phishing attack for example by tricking users into using a hyperlink pointing to a website controlled by an attacker.\n\nFix for 9.0.20 branch was released in version 9.0.20.238.\u00a0Fix for 9.0.21 branch was released in version 9.0.21.200. \n\n"
},
{
"lang": "es",
"value": "La falta de sanitizaci\u00f3n de entradas en las ramas 9.0.20 y 9.0.21 de BMC Control-M permite a los usuarios registrados manipular las p\u00e1ginas web generadas mediante la inyecci\u00f3n de c\u00f3digo HTML. Esto podr\u00eda conducir a un ataque de phishing exitoso, por ejemplo, enga\u00f1ando a los usuarios para que utilicen un hiperv\u00ednculo que apunte a un sitio web controlado por un atacante. La soluci\u00f3n para la rama 9.0.20 se lanz\u00f3 en la versi\u00f3n 9.0.20.238. La soluci\u00f3n para la rama 9.0.21 se lanz\u00f3 en la versi\u00f3n 9.0.21.200."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cvd@cert.pl",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.1,
"impactScore": 2.5
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7
}
]
},
"weaknesses": [
{
"source": "cvd@cert.pl",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-80"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*",
"versionStartIncluding": "9.0.20",
"versionEndExcluding": "9.0.20.238",
"matchCriteriaId": "87B57AF2-7AB2-48C3-A85B-A918033C70AF"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:bmc:control-m:*:*:*:*:*:*:*:*",
"versionStartIncluding": "9.0.21",
"versionEndExcluding": "9.0.21.201",
"matchCriteriaId": "8F86D69B-93E8-42A3-8D24-CDB59F33A388"
}
]
}
]
}
],
"references": [
{
"url": "https://cert.pl/en/posts/2024/03/CVE-2024-1604",
"source": "cvd@cert.pl",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://cert.pl/posts/2024/03/CVE-2024-1604",
"source": "cvd@cert.pl",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.bmc.com/it-solutions/control-m.html",
"source": "cvd@cert.pl",
"tags": [
"Product"
]
},
{
"url": "https://cert.pl/en/posts/2024/03/CVE-2024-1604",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://cert.pl/posts/2024/03/CVE-2024-1604",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.bmc.com/it-solutions/control-m.html",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
]
}
]
}