2024-12-08 03:06:42 +00:00

175 lines
6.0 KiB
JSON

{
"id": "CVE-2024-9997",
"sourceIdentifier": "psirt@autodesk.com",
"published": "2024-10-29T22:15:09.490",
"lastModified": "2024-11-01T16:27:34.960",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A maliciously crafted DWG file when parsed in acdb25.dll through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process."
},
{
"lang": "es",
"value": " Un archivo DWG creado con fines malintencionados, cuando se analiza en acdb25.dll a trav\u00e9s de Autodesk AutoCAD, puede provocar una vulnerabilidad de corrupci\u00f3n de memoria. Un actor malintencionado puede aprovechar esta vulnerabilidad para provocar un bloqueo, escribir datos confidenciales o ejecutar c\u00f3digo arbitrario en el contexto del proceso actual."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "psirt@autodesk.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "psirt@autodesk.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "8108219C-2977-47DF-8818-F7360E0AEA31"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_advance_steel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "583DCDB2-2170-4A06-B532-31886E2F1B12"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "A993F4D4-A2BA-42F7-B840-36BCCE6FF725"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_civil_3d:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "F4C616A7-A68D-42C5-88EB-9A6FE2C53116"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "F08AC00E-D022-401C-9A0F-55C5943591C8"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "889BB63A-C63B-4558-B1D6-49F76E1BB2C1"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "FA51DA68-070A-40F6-BF50-DBC31DCDD224"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "9DF22F44-1D3F-4F18-9835-8E0AE817377C"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "C1E9CD44-2AD4-4145-9816-60D0BD468D37"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.1.1",
"matchCriteriaId": "B6F2BC95-E948-4B22-9765-D5008ABD88E8"
}
]
}
]
}
],
"references": [
{
"url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021",
"source": "psirt@autodesk.com",
"tags": [
"Vendor Advisory"
]
}
]
}