"id": "CVE-2024-8933",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2024-11-13T04:15:05.037",
|
|
"lastModified": "2024-11-13T17:01:16.850",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel\nvulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of\nconfidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the\nlogical network while a valid user uploads or downloads a project file into the controller."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "CWE-924: Existe una vulnerabilidad de aplicaci\u00f3n inadecuada de la integridad de los mensajes durante la transmisi\u00f3n en un canal de comunicaci\u00f3n que podr\u00eda provocar la recuperaci\u00f3n del hash de la contrase\u00f1a, lo que podr\u00eda provocar la denegaci\u00f3n del servicio y la p\u00e9rdida de confidencialidad e integridad de los controladores. Para tener \u00e9xito, el atacante debe inyectarse dentro de la red l\u00f3gica mientras un usuario v\u00e1lido carga o descarga un archivo de proyecto en el controlador."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "HIGH",
|
|
"attackRequirements": "PRESENT",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "ACTIVE",
|
|
"vulnerableSystemConfidentiality": "HIGH",
|
|
"vulnerableSystemIntegrity": "HIGH",
|
|
"vulnerableSystemAvailability": "HIGH",
|
|
"subsequentSystemConfidentiality": "NONE",
|
|
"subsequentSystemIntegrity": "NONE",
|
|
"subsequentSystemAvailability": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirements": "NOT_DEFINED",
|
|
"integrityRequirements": "NOT_DEFINED",
|
|
"availabilityRequirements": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
|
|
"safety": "NOT_DEFINED",
|
|
"automatable": "NOT_DEFINED",
|
|
"recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED"
|
|
}
|
|
}
|
|
],
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.6,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-924"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/doc/SEVD-2024-317-02/SEVD-2024-317-02.pdf",
|
|
"source": "cybersecurity@se.com"
|
|
}
|
|
]
|
|
} |