2024-12-08 03:06:42 +00:00

104 lines
4.1 KiB
JSON

{
"id": "CVE-2024-8938",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2024-11-13T05:15:25.727",
"lastModified": "2024-11-13T17:01:16.850",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could\ncause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a\ncrafted Modbus function call to tamper with memory area involved in memory size computation."
},
{
"lang": "es",
"value": "CWE-119: Existe una vulnerabilidad de restricci\u00f3n inadecuada de operaciones dentro de los l\u00edmites de un b\u00fafer de memoria que podr\u00eda causar una posible ejecuci\u00f3n de c\u00f3digo arbitrario despu\u00e9s de un ataque Man-In-The-Middle exitoso seguido del env\u00edo de una llamada de funci\u00f3n Modbus manipulada para alterar el \u00e1rea de memoria involucrada en el c\u00e1lculo del tama\u00f1o de la memoria."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnerableSystemConfidentiality": "HIGH",
"vulnerableSystemIntegrity": "HIGH",
"vulnerableSystemAvailability": "HIGH",
"subsequentSystemConfidentiality": "NONE",
"subsequentSystemIntegrity": "NONE",
"subsequentSystemAvailability": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirements": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"automatable": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/doc/SEVD-2024-317-03/SEVD-2024-317-03.pdf",
"source": "cybersecurity@se.com"
}
]
}