René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

221 lines
6.3 KiB
JSON

{
"id": "CVE-2020-26922",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-10-09T07:15:17.857",
"lastModified": "2020-10-15T20:02:42.890",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a WC7500 versiones anteriores a 6.5.5.24, WC7600 versiones anteriores a 6.5.5.24, WC7600v2 versiones anteriores a 6.5.5.24 y WC9500 versiones anteriores a 6.5.5.24"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9
},
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.5,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.5.5.24",
"matchCriteriaId": "7C7EBAEB-4D71-4F10-8B42-F5C844E1B71E"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB22B065-8EC8-4DA7-984A-CCB6919AF8F3"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.5.5.24",
"matchCriteriaId": "93AD60DB-0EBB-467B-AD0C-5C107DCC446F"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc7600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF16A53E-FFFD-4F11-831A-82BB76675CBD"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.5.5.24",
"matchCriteriaId": "470918A5-9FE0-4F63-8455-5527CF138F54"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C8BB1F1-A12D-43CC-A6D0-9633E99D746B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.5.5.24",
"matchCriteriaId": "23E6496E-07CD-4191-B117-530D063514EE"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "113D0DF6-C719-4A43-80B2-463EC4323009"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}