"id": "CVE-2023-29460",
|
|
"sourceIdentifier": "PSIRT@rockwellautomation.com",
|
|
"published": "2023-05-09T14:15:13.217",
|
|
"lastModified": "2023-05-16T18:30:41.293",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow potentially\u00a0resulting in a complete loss of confidentiality, integrity, and availability.\n"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:arena_simulation:16.00.00:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "B42EE5A3-B6F0-4D21-B3F8-7EBBC5B8A53B"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:arena_simulation:16.20.00:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4FAF4B54-35C6-4D7F-B940-FC5C70B56BB8"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139391",
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"tags": [
|
|
"Permissions Required",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |