René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

149 lines
4.8 KiB
JSON

{
"id": "CVE-2020-10881",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"published": "2020-03-25T21:15:11.857",
"lastModified": "2020-03-31T17:26:21.017",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of TP-Link Archer A7 Firmware Ver: 190726 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of DNS responses. A crafted DNS message can trigger an overflow of a fixed-length, stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the root user. Was ZDI-CAN-9660."
},
{
"lang": "es",
"value": "Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario sobre las instalaciones afectadas de enrutadores AC1750 TP-Link Archer A7 Versi\u00f3n de Firmware: 190726. No es requerida una autenticaci\u00f3n para explotar esta vulnerabilidad. El fallo espec\u00edfico se presenta en el manejo de las respuestas DNS. Un mensaje DNS dise\u00f1ado puede desencadenar un desbordamiento de un b\u00fafer en la regi\u00f3n heap de la memoria de longitud fija. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del usuario root. Fue ZDI-CAN-9660."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:tp-link:ac1750_firmware:190726:*:*:*:*:*:*:*",
"matchCriteriaId": "484C6BBE-194A-4E40-A691-4D04D9DF519C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:tp-link:ac1750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D9017433-E653-4983-B0C4-B5AB9AF67AE4"
}
]
}
]
}
],
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-333/",
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
}
]
}