René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

125 lines
3.7 KiB
JSON

{
"id": "CVE-2020-15833",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-02-01T02:15:14.987",
"lastModified": "2021-02-04T15:23:34.747",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The Dropbear SSH daemon has been modified to accept an alternate hard-coded path to a public key that allows root access. This key is stored in a /rom location that cannot be modified by the device owner."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos Mofi Network MOFI4500-4GXeLTE versi\u00f3n 4.1.5-std. El demonio Dropbear SSH ha sido modificado para aceptar una ruta alternativa embebida para una clave p\u00fablica que permite el acceso root. Esta clave es almacenada en una ubicaci\u00f3n /rom que no puede ser modificada por el propietario del dispositivo"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.1.5-std:*:*:*:*:*:*:*",
"matchCriteriaId": "5911A292-8014-4E5F-B408-0A5788193E78"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C7B2A7E-0E09-412C-B540-9C5DFD16767D"
}
]
}
]
}
],
"references": [
{
"url": "https://mofinetwork.com/index.php?main_page=page&id=14",
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/",
"source": "cve@mitre.org",
"tags": [
"Technical Description",
"Third Party Advisory"
]
}
]
}