"id": "CVE-2020-27541",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2021-01-26T18:15:46.177",
|
|
"lastModified": "2021-02-02T18:49:12.507",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Denial of Service vulnerability in Rostelecom CS-C2SHW 5.0.082.1. AgentGreen service has a bug in parsing broadcast discovery UDP packet. Sending a packet of too small size will lead to an attempt of allocating buffer of negative size. As the result service AgentGreen will be terminated and started again later."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Una vulnerabilidad de Denegaci\u00f3n de Servicio en Rostelecom CS-C2SHW versi\u00f3n 5.0.082.1. El servicio AgentGreen presenta un error al analizar el paquete UDP de detecci\u00f3n de difusi\u00f3n. El env\u00edo de un paquete de tama\u00f1o demasiado peque\u00f1o conllevar\u00e1 a un intento de asignar un b\u00fafer de tama\u00f1o negativo. Como resultado, el servicio AgentGreen se terminar\u00e1 y se reiniciar\u00e1 m\u00e1s tarde"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 5.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:company:cs-c2shw_firmware:5.0.082.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "DA2108A4-A3BF-4ECE-99E7-9EE9233063EB"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:company:cs-c2shw:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C1CC4768-6258-44B3-9290-AF21DDB6E728"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://dil4rd.medium.com/groundhog-day-in-iot-valley-or-5-cves-in-1-camera-7dc1d2864707",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |