"id": "CVE-2020-28351",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-11-09T04:15:12.207",
"lastModified": "2020-11-18T15:15:50.070",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "The conferencing component on Mitel ShoreTel 19.46.1802.0 devices could allow an unauthenticated attacker to conduct a reflected cross-site scripting (XSS) attack (via the PATH_INFO to index.php) due to insufficient validation for the time_zone object in the HOME_MEETING& page."
},
{
"lang": "es",
"value": "El componente conferencing en los dispositivos Mitel ShoreTel versi\u00f3n 19.46.1802.0, podr\u00eda permitir a un atacante no autenticado conducir un ataque de tipo cross-site scripting (XSS) reflejado (por medio del par\u00e1metro PATH_INFO en el archivo index.php) debido a una comprobaci\u00f3n insuficiente para el objeto time_zone en la p\u00e1gina HOME_MEETING&"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE",
"baseScore": 4.3
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:mitel:shoretel_firmware:19.46.1802.0:*:*:*:*:*:*:*",
"matchCriteriaId": "99228794-9F81-4BAD-8877-BAAC7FAEA233"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:mitel:shoretel:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12AEEC72-E90B-4F7B-B332-E771944488F4"
}
]
}
]
}
],
"references": [
{
"url": "http://packetstormsecurity.com/files/159987/ShoreTel-Conferencing-19.46.1802.0-Cross-Site-Scripting.html",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "https://github.com/dievus/cve-2020-28351",
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.mitel.com/articles/what-happened-shoretel-products",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}