René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

305 lines
8.7 KiB
JSON

{
"id": "CVE-2020-35794",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-12-30T00:15:14.017",
"lastModified": "2020-12-30T21:23:57.013",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBS40V versiones anteriores a 2.6.1.4, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9
},
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.7,
"impactScore": 6.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"accessVector": "ADJACENT_NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 5.1,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.6.1.4",
"matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.15.25",
"matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.15.25",
"matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.15.25",
"matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.15.25",
"matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.15.25",
"matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.2.15.25",
"matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000062629/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0034",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}