mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
291 lines
9.0 KiB
JSON
291 lines
9.0 KiB
JSON
{
|
|
"id": "CVE-2020-6964",
|
|
"sourceIdentifier": "ics-cert@hq.dhs.gov",
|
|
"published": "2020-01-24T17:15:13.297",
|
|
"lastModified": "2020-03-17T17:22:33.297",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "En ApexPro Telemetry Server Versiones 4.2 y anteriores, CARESCAPE Telemetry Server Versiones v4.2 y anteriores, Clinical Information Center (CIC) Versiones 4.X y 5.X, CARESCAPE Central Station (CSCS) Versiones 1.X y CARESCAPE Central Station (CSCS) Versiones 2.X, el servicio integrado para el cambio de teclado de los dispositivos afectados podr\u00eda permitir a atacantes obtener acceso de entrada de teclado remoto sin autenticaci\u00f3n por medio de la red."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 8.6,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 4.0
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-306"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-306"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:apexpro_telemetry_server_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "4.2",
|
|
"matchCriteriaId": "4C5DD75E-7D4D-4B05-A84D-EDEAA2D23E59"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:gehealthcare:apexpro_telemetry_server:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "A94476A1-B004-4561-918D-C41631F36D9F"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:1.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "28F6C17B-2288-4EA1-B89F-6E1FED96ADD1"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mai700_firmware:2.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "9304DE75-4BCB-4C13-97D5-547195441591"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mai700:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4C2C8D13-A1C6-4DD1-9886-F925E2158C3A"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:1.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "85D5EF4C-F118-4CA9-93C1-6366303F8893"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:carescape_central_station_mas700_firmware:2.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "43F897B5-1F21-466D-A99C-2E6A98E93FFA"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:gehealthcare:carescape_central_station_mas700:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "42991B9E-1D70-4A40-A283-162F2A73669B"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:4.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "2FE710E0-76E4-4F7E-890C-9AEB00F5DB13"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100d_firmware:5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "68B32A68-64CF-4579-B465-F1B8F4997C48"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100d:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D0E93396-C7BB-4E53-8921-8251DC6A0F75"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:4.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "57D4B8E4-C481-446C-BF46-6FB6253344A1"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:clinical_information_center_mp100r_firmware:5.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "71F1DE32-2C25-4C0C-A4BF-30F5F3F19C70"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:gehealthcare:clinical_information_center_mp100r:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "057C6A3F-BD7E-4655-B9D9-1402C5259D59"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:gehealthcare:carescape_telemetry_server_mp100r_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "4.2",
|
|
"matchCriteriaId": "E7A592B9-9BE4-4096-B733-EE9A03D7A610"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:gehealthcare:carescape_telemetry_server_mp100r:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "636B9839-E067-4BB0-A5FF-F3B4BE12AB50"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"US Government Resource"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf",
|
|
"source": "nvd@nist.gov",
|
|
"tags": [
|
|
"Product"
|
|
]
|
|
}
|
|
]
|
|
} |