"id": "CVE-2020-6970",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2020-02-19T21:15:11.653",
"lastModified": "2020-02-28T18:54:27.857",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server."
},
{
"lang": "es",
"value": "Se encontr\u00f3 un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria en Emerson OpenEnterprise SCADA Server versi\u00f3n 2.83 (si las Interfaces Modbus o ROC se han instalado y est\u00e1n en uso) y todas las versiones de OpenEnterprise 3.1 hasta 3.3.3, donde un script especialmente dise\u00f1ado podr\u00eda ejecutar c\u00f3digo en el OpenEnterprise Server."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-122"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:emerson:openenterprise_scada_server:*:*:*:*:*:*:*:*",
"versionStartIncluding": "3.1",
"versionEndIncluding": "3.3.3",
"matchCriteriaId": "271688F8-AB9E-43BE-B46E-517F78D3D650"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:emerson:openenterprise_scada_server:2.8.3:*:*:*:*:*:*:*",
"matchCriteriaId": "652B19A1-64C4-4AD0-8833-BA076979B245"
}
]
}
]
}
],
"references": [
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-049-02",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
}
]
}