mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-29 01:31:20 +00:00
117 lines
3.4 KiB
JSON
117 lines
3.4 KiB
JSON
{
|
|
"id": "CVE-2020-8438",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2020-01-29T23:15:13.030",
|
|
"lastModified": "2020-01-31T20:32:51.713",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Ruckus ZoneFlex R500 104.0.0.0.1347 devices allow an authenticated attacker to execute arbitrary OS commands via the hidden /forms/nslookupHandler form, as demonstrated by the nslookuptarget=|cat${IFS} substring."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Los dispositivos Ruckus ZoneFlex R500 versi\u00f3n 104.0.0.0.1347, permiten a un atacante autenticado ejecutar comandos arbitrarios del sistema operativo por medio del formulario oculto de /forms/nslookupHandler, como es demostrado por la subcadena nslookuptarget=|cat${IFS}."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.2,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE",
|
|
"baseScore": 9.0
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 8.0,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-78"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:arris:ruckus_zoneflex_r500_firmware:104.0.0.0.1347:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E93046E9-6A17-4052-8A0B-07BA0B8773F5"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:arris:ruckus_zoneflex_r500:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F0EE0BD7-1B48-4AC4-A769-F12F303054FA"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://sku11army.blogspot.com/2020/01/ruckus-rce-ruckus-m500-via-injection-on.html",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |