René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

117 lines
3.4 KiB
JSON

{
"id": "CVE-2020-8438",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-01-29T23:15:13.030",
"lastModified": "2020-01-31T20:32:51.713",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Ruckus ZoneFlex R500 104.0.0.0.1347 devices allow an authenticated attacker to execute arbitrary OS commands via the hidden /forms/nslookupHandler form, as demonstrated by the nslookuptarget=|cat${IFS} substring."
},
{
"lang": "es",
"value": "Los dispositivos Ruckus ZoneFlex R500 versi\u00f3n 104.0.0.0.1347, permiten a un atacante autenticado ejecutar comandos arbitrarios del sistema operativo por medio del formulario oculto de /forms/nslookupHandler, como es demostrado por la subcadena nslookuptarget=|cat${IFS}."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:arris:ruckus_zoneflex_r500_firmware:104.0.0.0.1347:*:*:*:*:*:*:*",
"matchCriteriaId": "E93046E9-6A17-4052-8A0B-07BA0B8773F5"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:arris:ruckus_zoneflex_r500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0EE0BD7-1B48-4AC4-A769-F12F303054FA"
}
]
}
]
}
],
"references": [
{
"url": "https://sku11army.blogspot.com/2020/01/ruckus-rce-ruckus-m500-via-injection-on.html",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}