René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

163 lines
4.5 KiB
JSON

{
"id": "CVE-2021-30338",
"sourceIdentifier": "product-security@qualcomm.com",
"published": "2022-06-14T10:15:14.707",
"lastModified": "2022-06-23T19:30:30.453",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Improper input validation in TrustZone memory transfer interface can lead to information disclosure in Snapdragon Compute"
},
{
"lang": "es",
"value": "Una comprobaci\u00f3n de entrada inapropiada en la interfaz de transferencia de memoria TrustZone puede conllevar a una divulgaci\u00f3n de informaci\u00f3n en Snapdragon Compute"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6
},
{
"source": "product-security@qualcomm.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.5,
"impactScore": 4.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:N/A:N",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.9
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 3.9,
"impactScore": 6.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:qualcomm:sd850_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B1CA3237-5F9A-4490-A66B-853BE9310028"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:qualcomm:sd850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8F3601C-A801-4EBD-BDCC-2B84898DFBEA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:qualcomm:sdxr1_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7E8622BB-289F-4A61-A839-F42912A90449"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:qualcomm:sdxr1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17B2E7D7-A8C3-4EC9-9148-F048AFD03D98"
}
]
}
]
}
],
"references": [
{
"url": "https://www.qualcomm.com/company/product-security/bulletins/april-2022-bulletin",
"source": "product-security@qualcomm.com",
"tags": [
"Vendor Advisory"
]
}
]
}