"id": "CVE-2021-31755",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-05-07T23:15:07.047",
"lastModified": "2021-05-10T14:57:33.257",
"vulnStatus": "Analyzed",
"cisaExploitAdd": "2021-11-03",
"cisaActionDue": "2021-11-17",
"cisaRequiredAction": "Apply updates per vendor instructions.",
"cisaVulnerabilityName": "Tenda AC11 Up to 02.03.01.104_CN Stack Buffer Overflow",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos Tenda AC11 con firmware hasta 02.03.01.104_CN. Una vulnerabilidad de desbordamiento del b\u00fafer de la pila en /goform/setmac permite a los atacantes ejecutar c\u00f3digo arbitrario en el sistema a trav\u00e9s de una solicitud de correo manipulada"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:tenda:ac11_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "02.03.01.104_cn",
"matchCriteriaId": "08B4F9BE-9D0D-4297-A0EE-2B8D4853DD0E"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582"
}
]
}
]
}
],
"references": [
{
"url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Issue Tracking",
"Third Party Advisory"
]
}
]
}