"id": "CVE-2021-32458",
"sourceIdentifier": "security@trendmicro.com",
"published": "2021-05-27T11:15:07.313",
"lastModified": "2021-06-07T19:08:49.727",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Trend Micro Home Network Security version 6.6.604 and earlier is vulnerable to an iotcl stack-based buffer overflow vulnerability which could allow an attacker to issue a specially crafted iotcl which could lead to code execution on affected devices. An attacker must first obtain the ability to execute low-privileged code on the target device in order to exploit this vulnerability."
},
{
"lang": "es",
"value": "La versi\u00f3n 6.6.604 y anteriores de Trend Micro Home Network Security son vulnerables a una vulnerabilidad de desbordamiento del b\u00fafer basada en la pila de iotcl que podr\u00eda permitir a un atacante emitir un iotcl especialmente dise\u00f1ado que podr\u00eda conducir a la ejecuci\u00f3n de c\u00f3digo en los dispositivos afectados. Un atacante debe obtener primero la capacidad de ejecutar c\u00f3digo con pocos privilegios en el dispositivo de destino para poder explotar esta vulnerabilidad"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2
},
"baseSeverity": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:trendmicro:home_network_security:*:*:*:en:*:*:*:*",
"versionEndIncluding": "6.6.604",
"matchCriteriaId": "6CA71C14-AE1C-44AF-8CFF-8461DBA0CA78"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:trendmicro:home_network_security:*:*:*:ja:*:*:*:*",
"versionEndIncluding": "6.6.604",
"matchCriteriaId": "1EE779A2-BE6E-4EF1-B22E-D2ED7CA3C74D"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:trendmicro:home_network_security:*:*:*:zh:*:*:*:*",
"versionEndIncluding": "6.6.604",
"matchCriteriaId": "D5C7D541-00E5-4BF7-8191-9BA2BB5CD931"
}
]
}
]
}
],
"references": [
{
"url": "https://helpcenter.trendmicro.com/en-us/article/TMKA-10337",
"source": "security@trendmicro.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1231",
"source": "security@trendmicro.com",
"tags": [
"Third Party Advisory"
]
}
]
}