"id": "CVE-2021-37197",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2022-01-11T12:15:09.930",
|
|
"lastModified": "2022-04-30T02:26:16.707",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS is vulnerable to SQL injections. This could allow an attacker to execute arbitrary SQL statements."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en COMOS V10.2 (Todas las versiones s\u00f3lo si se utilizan componentes web), COMOS V10.3 (Todas las versiones anteriores a V10.3.3.3 s\u00f3lo si se utilizan componentes web), COMOS V10.4 (Todas las versiones anteriores a V10.4.1 s\u00f3lo si se utilizan componentes web). El componente COMOS Web de COMOS es vulnerable a inyecciones SQL. Esto podr\u00eda permitir a un atacante ejecutar sentencias SQL arbitrarias."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 6.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 6.8,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-89"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-89"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "10.2",
|
|
"matchCriteriaId": "28970CC4-B11E-4B5A-88D2-CA6528CAB36A"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "10.3",
|
|
"versionEndExcluding": "10.3.3.3",
|
|
"matchCriteriaId": "F4E2BA1A-7CCB-4785-82A3-27E21B83B0AB"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:comos:10.4:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "BDF6D202-6CF1-4B97-8386-AC05DBA41C5F"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-995338.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |