René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

117 lines
3.4 KiB
JSON

{
"id": "CVE-2021-46264",
"sourceIdentifier": "cve@mitre.org",
"published": "2022-02-15T20:15:07.650",
"lastModified": "2022-02-23T16:30:59.867",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the onlineList module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data."
},
{
"lang": "es",
"value": "Se ha detectado que el router Tenda AC Series versi\u00f3n AC11_V02.03.01.104_CN, contiene un desbordamiento del b\u00fafer de la pila en el m\u00f3dulo onlineList. Esta vulnerabilidad permite a atacantes causar una denegaci\u00f3n de servicio (DoS) por medio de datos de desbordamiento dise\u00f1ados"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:tenda:ac11_firmware:02.03.01.104_cn:*:*:*:*:*:*:*",
"matchCriteriaId": "F3B27213-BB07-4FC1-B1BD-27920A125681"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582"
}
]
}
]
}
],
"references": [
{
"url": "https://github.com/Ainevsia/CVE-Request/tree/main/Tenda/9",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}