2024-07-14 02:06:08 +00:00

125 lines
3.5 KiB
JSON

{
"id": "CVE-2022-27287",
"sourceIdentifier": "cve@mitre.org",
"published": "2022-04-10T21:15:08.827",
"lastModified": "2022-04-19T16:13:05.550",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link DIR-619 Ax v1.00 was discovered to contain a stack overflow in the function formSetWanPPPoE. This vulnerability allows attackers to cause a Denial of Service (DoS) via the curTime parameter."
},
{
"lang": "es",
"value": "Se ha detectado que D-Link DIR-619 Ax versi\u00f3n v1.00, contiene un desbordamiento de pila en la funci\u00f3n formSetWanPPPoE. Esta vulnerabilidad permite a atacantes causar una denegaci\u00f3n de servicio (DoS) por medio del par\u00e1metro curTime"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:dlink:dir-619_ax_firmware:1.00:*:*:*:*:*:*:*",
"matchCriteriaId": "D48B0114-A8E1-4A8C-9AEF-D3C6655F8994"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:dlink:dir-619_ax:-:*:*:*:*:*:*:*",
"matchCriteriaId": "42A0C34B-1D75-4328-8DD9-0FC055B805D3"
}
]
}
]
}
],
"references": [
{
"url": "https://github.com/wu610777031/IoT_Hunter/blob/main/DIR-619%20Buffer%20Overflow.pdf",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "https://www.dlink.com/en/security-bulletin/",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}