2024-12-08 03:06:42 +00:00

139 lines
4.5 KiB
JSON

{
"id": "CVE-2017-6048",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2017-05-19T03:29:00.543",
"lastModified": "2024-11-21T03:28:59.190",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A Command Injection issue was discovered in Satel Iberia SenNet Data Logger and Electricity Meters: SenNet Optimal DataLogger V5.37c-1.43c and prior, SenNet Solar Datalogger V5.03-1.56a and prior, and SenNet Multitask Meter V5.21a-1.18b and prior. Successful exploitation of this vulnerability could result in the attacker breaking out of the jailed shell and gaining full access to the system."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema de inyecci\u00f3n de comando en Concentradores de Medida y Medidores El\u00e9ctricos de Satel Iberia SenNet: SenNet Optimal DataLogger versiones V5.37c-1.43c y anteriores, SenNet Solar Datalogger versiones V5.03-1.56a y anteriores, y SenNet Multitask Meter versiones V5.21a-1.18b y anteriores. La explotaci\u00f3n con \u00e9xito de esta vulnerabilidad podr\u00eda resultar en que el atacante salga del shell enjaulado y alcance acceso completo al sistema."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"baseScore": 9.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": true,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:satel-iberia:sennet_multitask_meter:*:*:*:*:*:*:*:*",
"versionEndIncluding": "5.21a-1.18b",
"matchCriteriaId": "0CDC29E1-279D-4B5F-BB14-9844C4F7735F"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:satel-iberia:sennet_optimal_datalogger:*:*:*:*:*:*:*:*",
"versionEndIncluding": "5.37c-1.43c",
"matchCriteriaId": "D80453AB-DFA7-4BD9-8A43-DAFAD72480F2"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:satel-iberia:sennet_solar_datalogger:*:*:*:*:*:*:*:*",
"versionEndIncluding": "5.03-1.56a",
"matchCriteriaId": "C29D8235-23DA-4451-9EC2-FE0D04453AFC"
}
]
}
]
}
],
"references": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-02",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-02",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
]
}
]
}