"id": "CVE-2017-9940",
"sourceIdentifier": "productcert@siemens.com",
"published": "2017-08-08T00:29:00.417",
"lastModified": "2024-11-21T03:37:13.167",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network."
},
{
"lang": "es",
"value": "Se ha descubierto una vulnerabilidad en Siemens SiPass integrated (todas las versiones anteriores a la V2.70) que podr\u00eda permitir que un atacante con acceso a una cuenta de usuario con pocos privilegios leyese o escribiese archivos en el sistema de archivos del servidor SiPass integrated en la red."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N",
"baseScore": 5.5,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sipass_integrated:*:sp2:*:*:*:*:*:*",
"versionEndIncluding": "2.65",
"matchCriteriaId": "2375DDBA-DBFD-49DB-9B13-0D832E21146B"
}
]
}
]
}
],
"references": [
{
"url": "http://www.securityfocus.com/bid/99578",
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "http://www.securityfocus.com/bid/99578",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}