mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-06-07 05:28:59 +00:00
59 lines
2.7 KiB
JSON
59 lines
2.7 KiB
JSON
{
|
|
"id": "CVE-2024-1180",
|
|
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
|
|
"published": "2024-04-03T17:15:47.530",
|
|
"lastModified": "2024-04-03T17:24:18.150",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "TP-Link Omada ER605 Access Control Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Omada ER605. Authentication is required to exploit this vulnerability.\n\nThe specific issue exists within the handling of the name field in the access control user interface. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-22227."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo de inyecci\u00f3n de comando de control de acceso TP-Link Omada ER605. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de TP-Link Omada ER605. Se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. El problema espec\u00edfico existe en el manejo del campo de nombre en la interfaz de usuario de control de acceso. El problema se debe a la falta de validaci\u00f3n adecuada de una cadena proporcionada por el usuario antes de usarla para ejecutar una llamada al SYSTEM. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de la ra\u00edz. Era ZDI-CAN-22227."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "zdi-disclosures@trendmicro.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.8,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 0.9,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "zdi-disclosures@trendmicro.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-78"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-086/",
|
|
"source": "zdi-disclosures@trendmicro.com"
|
|
}
|
|
]
|
|
} |