"id": "CVE-2023-27857",
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"published": "2023-03-22T02:15:48.953",
"lastModified": "2024-01-09T02:31:27.647",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "\n In affected versions, a heap-based buffer over-read condition occurs when the message field indicates more data than is present in the message field\n\n\n\n in Rockwell Automation's ThinManager ThinServer.\u00a0\u00a0An unauthenticated remote attacker can exploit this vulnerability to crash ThinServer.exe due to a read access violation.\n\n\n\n \n\n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
},
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
},
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"versionStartIncluding": "11.0.0",
"versionEndExcluding": "11.0.5",
"matchCriteriaId": "87FE29AC-1AC8-4BEE-9C53-E03F30D8943D"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"versionStartIncluding": "11.1.0",
"versionEndExcluding": "11.1.5",
"matchCriteriaId": "A2A444C2-A733-48D6-8D60-D7DB93AF7A00"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"versionStartIncluding": "11.2.0",
"versionEndExcluding": "11.2.6",
"matchCriteriaId": "FC17AE85-2491-4E52-AF74-39A0DE8C7599"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"versionStartIncluding": "12.0.0",
"versionEndExcluding": "12.0.3",
"matchCriteriaId": "E4E20E28-04AF-4797-8F7C-7406897C078B"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"versionStartIncluding": "12.1.0",
"versionEndExcluding": "12.1.4",
"matchCriteriaId": "681995A2-01BD-4ADA-A6B4-256E9EA73591"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:13.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FA8090-F7EB-4C5D-AD9D-7D82F34F34D1"
}
]
}
]
}
],
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1138640",
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Vendor Advisory"
]
}
]
}