"id": "CVE-2023-24565",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2023-02-14T11:15:16.223",
|
|
"lastModified": "2024-11-21T07:48:08.330",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
|
|
"baseScore": 3.3,
|
|
"baseSeverity": "LOW",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 1.4
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
|
|
"baseScore": 5.5,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2210.0002.004",
|
|
"matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |