2025-01-31 17:04:00 +00:00

182 lines
5.0 KiB
JSON

{
"id": "CVE-2023-27518",
"sourceIdentifier": "vultures@jpcert.or.jp",
"published": "2023-05-23T02:15:09.743",
"lastModified": "2025-01-31T15:15:08.247",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow vulnerability in the multiple setting pages of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to execute arbitrary code."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:contec:sv-cpt-mc310f_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "8.10",
"matchCriteriaId": "825C8DE5-2210-4274-81EE-E57DD13F74F7"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:contec:sv-cpt-mc310f:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CAC9BA1B-C65A-4EEA-AAD6-88685BC7A4FA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:contec:sv-cpt-mc310_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "8.10",
"matchCriteriaId": "DC74EAB1-C008-4DD5-AF3B-78F6171799DE"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:contec:sv-cpt-mc310:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F9FCCA5E-19F8-47D9-A6C6-77AF2AEFD51A"
}
]
}
]
}
],
"references": [
{
"url": "https://jvn.jp/en/vu/JVNVU92106300/",
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_solarview_230508.pdf",
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.contec.com/jp/download/donwload-list/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e#firmware",
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://jvn.jp/en/vu/JVNVU92106300/",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_solarview_230508.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.contec.com/jp/download/donwload-list/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e#firmware",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}