2024-12-15 03:03:56 +00:00

107 lines
3.5 KiB
JSON

{
"id": "CVE-2023-35796",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-10-10T11:15:11.733",
"lastModified": "2024-11-21T08:08:43.457",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINEMA Server V14 (todas las versiones). La aplicaci\u00f3n afectada sanitiza incorrectamente ciertos datos de configuraci\u00f3n SNMP recuperados de los dispositivos monitorizados. Un atacante con acceso a un dispositivo monitorizado podr\u00eda realizar un ataque de Cross-Site Scripting (XSS) almacenado que puede llevar a la ejecuci\u00f3n de c\u00f3digo arbitrario con privilegios \"SYSTEM\" en el servidor de aplicaciones. (ZDI-CAN-19823)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.6,
"impactScore": 6.0
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.3,
"impactScore": 6.0
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinema_server:14.0:*:*:*:*:*:*:*",
"matchCriteriaId": "85D4624C-8FF6-43E7-9098-5BD106EF6972"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}