2024-12-08 03:06:42 +00:00

251 lines
7.1 KiB
JSON

{
"id": "CVE-2023-40069",
"sourceIdentifier": "vultures@jpcert.or.jp",
"published": "2023-08-18T10:15:12.653",
"lastModified": "2024-11-21T08:18:38.257",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "OS command injection vulnerability in ELECOM wireless LAN routers allows an attacker who can access the product to execute an arbitrary OS command by sending a specially crafted request. Affected products and versions are as follows: WRC-F1167ACF all versions, WRC-1750GHBK all versions, WRC-1167GHBK2 all versions, WRC-1750GHBK2-I all versions, and WRC-1750GHBK-E all versions."
},
{
"lang": "es",
"value": "La vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo en los routers LAN inal\u00e1mbricos ELECOM permite a un atacante que pueda acceder al producto ejecutar un comando arbitrario del sistema operativo enviando una solicitud especialmente dise\u00f1ada. Los productos y versiones afectados son los siguientes WRC-F1167ACF todas las versiones, WRC-1750GHBK todas las versiones, WRC-1167GHBK2 todas las versiones, WRC-1750GHBK2-I todas las versiones y WRC-1750GHBK-E todas las versiones.\n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:elecom:wrc-f1167acf_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0233A6C1-4F74-4347-B204-899F0504E713"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:elecom:wrc-f1167acf:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C244EA13-D45C-4968-A330-3AD80F588537"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:elecom:wrc-1750ghbk_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E00CABDD-B213-4DAA-9FC4-D907AC465134"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:elecom:wrc-1750ghbk:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5D1F1675-60C1-4150-8306-1592F88D3DAC"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:elecom:wrc-1167ghbk2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07F1B061-C150-4DED-B3DE-B6DDB67AF1C4"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:elecom:wrc-1167ghbk2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7DF1D75E-EF09-4BF7-AC5C-F6CDC5B6ED8E"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:elecom:wrc-1750ghbk2-i_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "491E938A-060D-4A3E-B466-F2BC12DEF9F1"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:elecom:wrc-1750ghbk2-i:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E1EAF366-E7EB-4864-BB1C-16D828141CFD"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:elecom:wrc-1750ghbk-e_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "680D6E21-6065-4FCA-A8E6-DF53BD2E4927"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:elecom:wrc-1750ghbk-e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DDB8292C-ABDA-4F61-8EF1-D498AE3BF66C"
}
]
}
]
}
],
"references": [
{
"url": "https://jvn.jp/en/vu/JVNVU91630351/",
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/",
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://jvn.jp/en/vu/JVNVU91630351/",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.elecom.co.jp/news/security/20230810-01/",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}