"id": "CVE-2023-45793",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-03-12T11:15:47.503",
"lastModified": "2024-11-21T08:27:22.077",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Siveillance Control (All versions >= V2.8 < V3.1.1). The affected product does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Siveillance Control (Todas las versiones &gt;= V2.8 &lt; V3.1.1). El producto afectado no comprueba correctamente la lista de grupos de acceso asignados a un usuario individual. Esto podr\u00eda permitir que un usuario que haya iniciado sesi\u00f3n localmente obtenga privilegios de escritura para objetos donde solo tiene privilegios de lectura."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-863"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-145196.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-145196.html",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
]
}