"id": "CVE-2013-4860",
"sourceIdentifier": "cve@mitre.org",
"published": "2014-06-05T20:55:05.517",
"lastModified": "2024-11-21T01:56:35.047",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Radio Thermostat CT80 And CT50 with firmware 1.4.64 and earlier does not restrict access to the API, which allows remote attackers to change the operation mode, wifi connection settings, temperature thresholds, and other settings via unspecified vectors."
},
{
"lang": "es",
"value": "Radio Thermostat CT80 And CT50 con firmware 1.4.64 y anteriores no restringe acceso a la API, lo que permite a atacantes remotos cambiar el modo de operaci\u00f3n, configuraciones de conexi\u00f3n wifi, umbrales de temperatura y otras configuraciones a trav\u00e9s de vectores no especificados."
}
],
"metrics": {
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"baseScore": 8.3,
"accessVector": "ADJACENT_NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 6.5,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-264"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:radiothermostat:ct50_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.4.64",
"matchCriteriaId": "3625C99D-EAB1-4919-A708-FDD59C5745A0"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:h:radiothermostat:ct50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "13E0CACE-02E9-4250-AF18-C841F6859D49"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:radiothermostat:ct80_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.4.64",
"matchCriteriaId": "371ED3AC-FC4B-4BD7-A29F-B166D0245E1B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:h:radiothermostat:ct80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1837925F-485B-49DF-9C29-094C8721D5AC"
}
]
}
]
}
],
"references": [
{
"url": "http://packetstormsecurity.com/files/122657/Radio-Thermostat-Of-America-Inc-Lack-Of-Authentication.html",
"source": "cve@mitre.org"
},
{
"url": "http://www.securityfocus.com/bid/61581",
"source": "cve@mitre.org"
},
{
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/86197",
"source": "cve@mitre.org"
},
{
"url": "http://packetstormsecurity.com/files/122657/Radio-Thermostat-Of-America-Inc-Lack-Of-Authentication.html",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/61581",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/86197",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
]
}