"id": "CVE-2018-18330",
"sourceIdentifier": "security@trendmicro.com",
"published": "2018-12-21T15:29:00.280",
"lastModified": "2024-11-21T03:55:43.630",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An Address Bar Spoofing vulnerability in Trend Micro Dr. Safety for Android (Consumer) versions 3.0.1324 and below could allow an attacker to potentially trick a victim into visiting a malicious URL using address bar spoofing on the Private Browser of the app on vulnerable installations."
},
{
"lang": "es",
"value": "Una vulnerabilidad de suplantaci\u00f3n de la barra de direcciones en Trend Micro Dr. Safety for Android (Consumer), en versiones 3.0.1324 y anteriores, podr\u00eda permitir que un atacante enga\u00f1e a una v\u00edctima para que visite una URL maliciosa mediante la suplantaci\u00f3n de la barra de direcciones en el navegador privado de la aplicaci\u00f3n en instalaciones vulnerables."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"baseScore": 4.3,
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:trendmicro:dr._safety:*:*:*:*:*:android:*:*",
"versionEndIncluding": "3.0.1324",
"matchCriteriaId": "8C8D7032-BD35-4E1A-8598-672A2A41F52A"
}
]
}
]
}
],
"references": [
{
"url": "https://esupport.trendmicro.com/en-us/home/pages/technical-support/1121673.aspx",
"source": "security@trendmicro.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://esupport.trendmicro.com/en-us/home/pages/technical-support/1121673.aspx",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}